Accuracy of AS-OCT muscle insertion measurements

Anterior segment - optical coherence tomography (AS-OCT) is a non-contact imaging method that can provide accurate measures of extraocular muscles to limbus insertion distances. The authors evaluated the accuracy of AS-OCT for locating horizontal extraocular muscle insertions after strabismus surgery...

Accuracy of ASOCT muscle insertion measurements

Anterior segment optical coherence tomography (ASOCT) is a non-contact imaging method that can provide accurate measures of extraocular muscles to limbus insertion distances. The authors evaluated the accuracy of ASOCT for locating horizontal extraocular muscle insertions after strabismus surgery in...

Macular atrophy and choriocapillaris nonperfusion

This Japanese study compared the choriocapillaris (CC) nonperfusion area as measured on OCTA with areas of macular atrophy (MA) measured by fundus autofluoresence (FAF). A total of 44 eyes were assessed (31 were treated with anti-VEGF alone and 13 had...

Corneal lenticule allotransplant

This animal study looked at corneal lenticule allograft transplantation in rabbits. Seven rabbits underwent small incision lenticule extraction (SMILE) procedures, where their stromal lenticules were extracted and transplanted fresh into pre-prepared corneal stromal pockets of seven recipient eyes. Animals were...

Survey of paediatric ophthalmology practice in the US

The purpose of this study was to develop a survey to assess possible solutions for an economic turnaround in paediatric ophthalmology. A 12-item survey was circulated with questions related to practice location, setting and years in practice. Responses were received...

Central corneal and epithelial thickness measured by Fourier domain OCT

This study examined intraobserver and interobserver reproducibility of corneal thickness (CT) and epithelial thickness (ET) measurement of Fourier domain OCT (RTVue) in 23 healthy volunteers. RTVue is capable of producing 26,000 A scans per second with depth resolution of 5µm....

Swept source anterior segment OCT

The authors describe a study using the Casia OCT which is a swept source OCT to determine the visibility of the angle structures using two imaging protocols; high density and low density. They randomly selected one eye from 30 normal...

Cutting-edge practice in glaucoma care: what, how and why?

More effective treatments and drug delivery modalities, implantable minimally invasive glaucoma surgical (MIGS) devices, as well as accelerating clinical research programmes, will transform the surgical and clinical management of glaucoma in the near future. There is also an ever-greater emphasis...

Comparison of ketorolac 0.4% and nepafenac 0.1% for the prevention of CMO after phacoemulsification

This is a prospective randomised clinical trial study including patients older than 40 years with age related cataract and normal ophthalmic examination. The patients are randomised into three different groups and the objective of the study is to compare the...

Retrograde maculopathy in glaucoma

Macular optical coherence tomography (OCT) analysis can be used for quantitative measures of optic nerve atrophy at a location far away from the optic nerve head. This has recently led to the discovery of microcystic macular oedema (MME), in the...

Macular slippage following macular hole surgery

The treatment of macular holes now involves peeling the internal limiting membrane (ILM) as well as vitrectomy and gas tamponade. It has been noted in previous studies that following an ILM peel the morphology of the macula is different. Tadayoni...